Wall package is one of the best and most popular heating appliances in the house, which in addition to providing hot water, also provides hot water needed for the boiler and heating appliances. With the onset of the cold season, wall packages are used again, but it is better to do the wall package service before the cold days start and to make the necessary repairs for it if necessary.
The wall package provides the domestic hot water for bathing and washing, as well as the hot water needed for the radiator, and with its use, there is no more noise and noise in the engine room. The package is actually a small engine house that is installed separately for each residential unit and has become very popular due to its high efficiency and less space.
Wall packages have many advantages over the boiler and engine room system and water heaters, the most important of which are easy and fast access to hot water, the independence of the wall package of each unit of the whole building, adjusting the temperature of water and radiators to the desired size, occupation He noted less space in the house, reduced maintenance costs, optimal fuel consumption and high efficiency. Timely service of the wall package is the best way to maintain this widely used device, which greatly reduces the possible damages and incidental costs of servicing and repairing this device.
Butane gas boiler repair
In order to troubleshoot and repair the butane gas boiler and solve its problems, you need to have enough information about the error codes of this package. Below we review the butane package errors in different models.
Error code of butane package model 324
Red one tenth of a second (flashing red flashes once every tenth of a second six times per second) NTC piece
Red five tenths of a second (blinking in a row) Consumption potentiometer piece between 80 and 70 heating
Fixed red (flashes once every second) Fault, malfunction or malfunction of double heat switch or thermostat, no flame formation, sensor ignition gas valve,
✔ Red every second (flashes twice every second) Torch does not light up between two or three ignition cycles
✔ Red every one second (beats twice every second) Defective water pressure switch or two-amp fuse
Error code of Alta type butane package
✔ Fixed yellow: Consumption, NTC consumption is disconnected
Flashing yellow: The status of the maximum power of the amount consumed is the power of the device
Fixed red: NTC smoke thermostat heating, no flame formation, control board defective, minimum water pressure switch
Flashing red: The thermal switch is operated
Fixed green light: The torch is on
Flashing green light for one to five seconds: The system is in standby mode five times per second. No request has been issued.
✔ Fast flashing green light: Limited input and output, check input and output.
✔ Flashing green light every five tenths of a second: winter mode, standby mode, smoke pressure, pump set fan set, minimum water pressure switch fault for up to ten minutes, NTC false resistance lock, condenser switch fault
Optima model butane package error codes
If your device shows one of the items listed below, be sure to contact a DJI dealer at the earliest opportunity.
Fixed yellow: Consumption, NTC disconnected
Blinking yellow: Maximum power status, the amount of power consumption is more than the device.
✔ Fixed red: NTC smoke thermostat heating, no flame formation, control board, minimum water pressure switch fault
Flashing red: The thermal switch is operated
Fixed green light: The torch is on
✔ Flashing green light five times per second:: The system is in standby mode five times per second. No request has been issued.
✔ Fast flashing green light: Limited input and output, check input and output.
✔ Flashing green light every five tenths of a second: winter mode, standby mode, smoke pressure, pump set fan set, minimum water pressure switch fault for up to ten minutes, NTC false resistance lock, condenser switch fault
If your package shows such error codes or errors, it means that the device needs to be repaired. The error codes include: flashing summer winter lights, A01, A02, A03, A04, A06, A07, A11, ADG
Error code of butane package model of Perla device
ADG, E01, E02, E03, E04, E06, E07, E011, flashing lights and temperature
Calda model butane package error code
Fixed red: Function or breakdown of the thermal switch or breakdown of the smoke thermostat
Flashing Red: Definitive in NTC
✔ Red Yellow, Yellow Simultaneous: Minimum water pressure switch fault
Calda venezia butane package repair
Flashing yellow: Suped or maximum power status
Fixed yellow: The NTC sensor is disconnected
Flashing green one to five seconds: standby, no demand for use
✔ Fixed green: lighted torch
✔ Blinking green every five tenths of a second: winter mode, standby mode, smoke suppressor, pump page jammer
✔ Quick flashing green: Check control system
✔ Fixed red: NTC sensor, smoke thermostat heating, no flame formation control board
✔ Blinking red
In general, we have two types of defects in the wall-mounted boiler system:
1- First, the defects that are identified by the electronic board and will be notified to you by the error code. Of course, this error code in the analog package is determined by the blinking of one or more lights, and in digital packages, this error code appears on the monitor.
To repair the package and troubleshoot such defects, first of all, you should refer to the error code page of wall-mounted radiators, which is also available in the site menu, and use the error codes announced on this page to describe the troubleshooting that you see. There is a defect.
2- Troubleshooting defects that do not report any errors but disrupt the operation of the package. In the following, by providing some examples, we will examine some of these defects that disrupt the operation of the package but the electronic board is not able to detect them.
Radiators do not have adequate heat:
Before any action, make sure that the radiators are ventilated and the package load pressure is adjusted.